Recall: Honeywell Miller H500

December 23, 2025

Honeywell Fall Protection France SAS is recalling the Honeywell Miller branded H500 series harnesses produced between 1 March and 30 June 2025 at the Nabeul, Tunisia production facility. The affected products can be identified by their manufacturing date, article number and manufacturing location, which are indicated on the product label. The product was sold through distributors.

     

Affected models

Above pictures show an illustrative example for each configuration of H500 Series Harnesses

The article numbers concerned are listed in the following table:

Article Number Designation
1036081 H500 Pad QB 2D size 1
1036082 H500 Pad QB 2D size 2
1036083 H500 Pad QB 2D size 3
1036085 H500 Pad QB 2LO size 1
1036086 H500 Pad QB 2LO size 2
1036087 H500 Pad QB 2LO size 3
1036093 H500 QB size 1
1036095 H500 QB size 3
1036096 H500 MB 2D size 0
1036097 H500 MB 2D size 1
1036098 H500 MB 2D size 2
1036099 H500 MB 2D size 3
1036100 H500 QB 2D size 0
1036101 H500 QB 2D size 1
1036105 H500 QB 2LO size 0
1036106 H500 QB 2LO size 1
1036107 H500 QB 2LO size 2
1036108 H500 QB 2LO size 3
1036109 H500 QB 2LO Q-Fit size 1
1036110 H500 QB 2D size 2
1036111 H500 QB 2D size 3
1036121 H500 QB 2LO Q-Fit size 2
1036122 H500 QB 2LO Q-Fit size 3
1036123 H500 QB 2LO Ylow HV size 1
1036124 H500 QB 2LO Ylow HV size 2
1036125 H500 QB 2LO Ylow HV size 3
1036126 H500 QB 2D Ylow HV size 1
1036127 H500 QB 2D Ylow HV size 2
1036128 H500 QB 2D Ylow HV size 3
1036130 H500 QB 2LO Oran HV size 2
1036131 H500 QB 2LO Oran HV size 3
1036133 H500 QB 2D Oran HV size 2
1036134 H500 QB 2D Oran HV size 3
1036591 EDGE TESTED ROOFING KIT - H500
1036592 EDGE TESTED MAINTENANCE PSS KIT - H500
1036595 SCAFFOLDING PSS KIT - H500
1036597 SCAFFOLDING TURBOLITE PSS KIT - H500
1036598 H500 IC6 COMFORT HARNESS KIT - SIZE 2
3007-3736-001 H500 Mobile Platform KIT Size 2

WHY IS THIS PRODUCT DANGEROUS?

A limited number of units of the H500-Series Harnesses produced at the Nabeul, Tunisia facility between March 1, 2025, and June 30, 2025 may have been assembled with incorrect webbing routing through the front/sternal D-ring and/or leg buckles, posing a serious safety risk. This deviation may severely limit or even completely disable the safety function of the harness in the event of a fall from height. In specific circumstances, the front/sternal D-ring and leg buckles may not be able to withstand the necessary load requirements. This could result in serious, potentially fatal, injuries.

WHAT TO DO?

Please stop using the H500 harness that you purchased immediately and follow the steps below to check whether your product is potentially affected.

If your product is identified as affected, please continue to refrain from using it. In this case, we kindly ask you to contact us (contact details below). You will be informed by e-mail about the specific procedure for return.

First, locate the manufacturing label on your H500-series harness model.

Step 1: Article Number

Please check whether the Article Number indicated on your product is included in the table above.

  • If the Article Number on the manufacturing label of your H500 product is not listed in the table above, the unit is compliant—no further action needed.
  • If the Article Number on the manufacturing label of your H500 product is listed in the table above, proceed to Step 2

Step 2: Manufacturing location

Please check where your product was produced.

  • If the label states, "Made in Slovakia," the unit is compliant—no further action is needed.
  • If it states, "Made in Tunisia", please proceed to Step 3

Step 3: Manufacturing date

Please check if your product was produced between March 1, 2025, and June 30, 2025, if yes, please contact us (contact details below).

  • If the manufacturing date indicated on the label of your product is outside the date range stated above, the unit is compliant—no further action is needed. You may continue to use the harness.
  • If it is INSIDE the date range stated directly above —please contact us (contact details below).

REMEDIES FOR CONSUMERS

Honeywell Fall Protection France SAS will examine the returned products. If your harness is not affected, we will of course return it to you as quickly as possible and free of charge. If your harness is found to be affected by the safety issues described above, Honeywell Fall Protection France SAS will contact you immediately and provide one of the following remedies free of charge:

1.Repair of the affected harness to restore full compliance with the applicable safety and performance requirements; or
2.Replacement of the affected harness with a new product of the same type that meets all applicable safety and quality specifications. Contact our customer service team via e-mail (contact details below) for return shipping labels and instructions.

CONTACT

Consumers seeking further information regarding this recall may contact our customer service team via e-mail:

Countries Customer Service Mailbox
France, French overseas departments and territories advroissy.hspf@honeywell.com
United Kingdom, Ireland info-uk.hsp@honeywell.com
Belgium, Luxembourg, Netherlands info-benelux.hsp@honeywell.com
Austria, Switzerland, Germany info-germany.hsp@honeywell.com
Italy info-italia.hsp@honeywell.com
Sweden, Norway, Finland, Denmark, Iceland info-nordic.hsp@honeywell.com
Poland, Slovakia, Romania, Czech Republic, Slovenia, Estonia, Croatia, Bulgaria, Latvia, Lithuania info-poland.hsp@honeywell.com
Spain, Portugal, Greece, Cyprus, Malta SP56SALESSPAIN@Honeywell.com
Hungary info-hungary.hsp@honeywell.com

We sincerely apologize for any inconvenience this may cause and ask for your understanding as we take this measure in the interest of your safety.

Please inform others about this recall, especially if you know someone who has been offered, lent, or sold the recalled product.